M7800 Ultra HPHT Hematite Rheometer



Designed to completely isolate magnet from testing sample
The U.S. patented design allows separation of magnet from testing samples, and is especially suitable for hematite types of mud and liquid samples reactive to magnets.

Engineered to provide ultra-high pressure testing & easy operation
The M7800 HPHT Hematite Rheometer can apply pressure to the pressure chamber as high as 40,000 psi, giving the researcher a pressure environment range greater than any competing instrument, while providing easy operation and simple maintenance.

Unlike the standard operation of a rheometer which operates via magnetic coupling, the Grace Instrument M7800 Ultra HPHT Hematite Rheometer is configured to keep the magnets completely separated from the tested fluid. This helps ensure that test results are free of magnetically-induced errors.

Simple Setup, Easy Operation, Reliable & Repeatable Testing
The patented M7800 design modifies the M7500 cell tower hardware to enable test pressures of up to 40,000 psi. Like the M7500, The M7800 is built with a thick-walled steel pressure cell, which is surrounded by a fail-safe steel containment vessel to ensure operator safety.

U.S. Patents: 8,813,542, 7,412,877, and 7,287,416
Dimensions: 22" height x 12" width x 24" depth (tower) or 12" height x 25" width x 15.5" depth (cab)
Weight: 280 lbs.
Construction: Stainless Steel
Temperature Range: Ambient (20°F with chiller) to 600°F (315°C)
Pressure Range: Atm to 40,000 psi
Speed Range: 0.01 - 600 rpm continuous
Viscosity: 0.5 to 5,000,000 Centipose
Torque: 7 μNm to 10 mN.m
Shear Rate: 0.0082 to 1020 S-1
Sheer Stress: 2 to 10,000 dyn/cm2
Repeatability: ±1% of full scale range or better
Resolution: 0.3% of full scale range or better
Power Supply: 120 VAC or 240 VAC (with transformer)
Coolant Supply: Tap water or chiller
Compressed Air: 120 psi
Sample Size: 132 mL (depends on bob size)
Computer Requirements: PC with MS Windows 9X/2000/XP/Vista/7/8/10/11
  • Intended for use in rheological testing of magnetically-sensitive fluids such as those containing hematite.
  • Configured to keep magnets completely separated from the testing fluid. This helps ensure that test results are free of magnetically-induced errors.
  • Pressurizes the pressure chamber up to 40,000 psi, giving the researcher a pressure environment range greater than any competing instrument, while providing easy operation and simple maintenance.
  • Built with a thick-walled pressure cell, which is surrounded by a fail-safe steel containment vessel to ensure operator safety.
  • Cell tower is patented
  • For use with the M7500 Ultra HPHT Rheometer
Downloads for the M7800 Ultra HPHT Hematite Rheometer: