Foam & Core Flow Tester
M9300 HPHT Foam Loop & Core Flow Tester
- The 9000 series products are all customizable.
The only integrated foam loop/core flow tester on the market today
The Grace Instrument M9300 HPHT Foam Loop & Core Flow Tester combines the operation of a foam loop system with a formation damage evaluation system.
It can measure permability changes to a formation core in a high temperature and high pressure environment, after injecting the formation core with fluids,
such as various foams, fracturing fluids, drilling muds, completion fluids and acids.
The M9300 can be operated in one of three modes:
- HPHT Foam Loop Rheometer system can be used for foam creation, rheology and quality evaluation (bubble size distribution, half-life and density, etc.).
- HPHT Automatic Core Flow Tester (Formation Damage) system can be used for core fluid treatments and permeability analysis.
- Combined HPHT Foam Loop Rheometer & HPHT Automatic Core Flow Tester system is capable of measuring dynamic leakoff of foam, damage to the formation, well stimulation effects of foam, and rheology of foam in porous media.
HPHT Foam Loop Rheometer | HPHT Automatic Core Flow Tester | Combined HPHT Foam Loop Rheometer & HPHT Automatic Core Flow Tester |
---|---|---|
Temperature Range: Amb. to 350°F |
Temperature Range: Amb. to 350°F |
Temperature Range: 70°F to 350°F |
Operating Pressure: Atm. to 5,000 psi |
Working Pressure: Atm. to 10,000 psi |
Operating Pressure: Atm. to 5,000 psi |
-- | Confining Pressure: Atm. to 15,000 |
Confining Pressure: Atm. to 5,000 psi |
Flow Rate Range: 0 to 375 ml/min |
Flow Rate Range: 0 to 60 ml/min |
-- |
Shear Rate: 0 to 1,500 S-1 |
-- | Shear Rate: 0 to 1,500 S-1 |
-- | Back Pressure: Atm to 10,000 psi |
Back Pressure: Atm to 10,000 psi |
Microscope Magnification: 11 to 144 X |
-- | -- |
Viewing Window: Quartz |
-- | -- |
Rheology Characterization: API Standard Rheological and Shear History |
-- | -- |
Foam Density: 0.3 to 1.0 g/cm3 controllable |
-- | -- |
Half-life of Foam: 0 to 72 hr |
-- | -- |
Diameter of Visible Foam Bubble: ≥ 1 μm |
-- | -- |
- Combines operation of a foam loop system with a formation damage evaluation system.
- Foam generation & foam loop system can be used for foam creation, rheology and quality evaluation.
- Formation damage (core flow) system can be used for core fluid treatments and permeability analysis.
- Can be built to custom specifications.
Downloads for the M9300 HPHT Foam Loop & Core Flow:
Read more about our instrument's technical applications within these scientific and academic publications:
-
Energy, Volume 264, 1 February 2023, 126256 2023
Polymer Enhanced Foam For Improving Oil Recovery in Oil-Wet Carbonate Reservoirs: A Proof of Concept and Insights Into the Polymer-Surfactant Interactions
A schematic diagram of the Grace M9300 core flow tester is shown in Fig. 1, which displays an illustration demonstrating the foam flooding process involving surfactant solution and nitrogen.
https://www.sciencedirect.com/science/article/pii/S0360544222031425 -
Energy, Volume 313, 1 April 2022, 122684 2022
An Experimental Investigation of the Foam Enhanced Oil Recovery Process For a Dual Porosity and Heterogeneous Carbonate Reservoir Under Strongly Oil-Wet Condition
A schematic diagram of the Grace M9300 core flow tester is shown in Fig. 1, depicting the proposed foam flooding process.
https://www.sciencedirect.com/science/article/pii/S0016236121025503