PVT System
M9700 HPHT PVT System
- The 9000 series of products are customizable.
- Dimensions: Custom
- Weight: Custom
PVT system that provides accurate, repeatable results
The Grace Instrument M9700 HPHT PVT System studies the phase behavior
of hydrocarbon fluids. The system is mercury-free, featuring a hydraulic
syringe pump which generates the required pressure for testing. Test fluid
volume is monitored for expansion or contraction while under varying conditions of pressure, volume, and temperature (PVT). These conditions are
computer-controlled and are completely customizable through user-designed
test sequences created with the included PC software; the M9700’s software
is installed on a Windows PC that is included with the machine. This multifunctional system can also perform as a recombination cell.
M9700 HPHT PVT System’s hardware
The M9700 HPHT PVT System uses a syringe pump to push its piston,
resulting in a compact and economic PVT system. Its hydraulic piston
controls the pressure and volume in the cell.
The PVT’s pressure cell features a transparent sapphire window on one end,
allowing visual observation of the sample fluid during a test. All M9700s
come with a camera that can be mounted to it, so a live video feed can be
displayed on our custom software as it records video.
The M9700 HPHT PVT System can pressurize and heat the fluids while
stirring them. The system does so using a magnetic stirrer and an automatic
rocking system.
Multiple test options for comprehensive PVT testing
The M9700 HPHT PVT System gives the operator the greatest possible
number of options for testing parameters. Extremely high-resolution measurement of pressure, temperature, phase, vapor, liquid volume, gas volume,
and more can all be tracked accurately and repeatably by the computercontrolled sensors and the state-of-the-art data analysis software that powers
the entire system.
The PVT System can perform many tests, including: constant mass expansion (CME) tests, constant mass depletion (CMD) tests, differential vaporization (DV) studies, constant volume depletion (CVD) tests, swelling tests,
separator tests, and more. During test operations, the software records test
data, including: pressure, total volume, retrograde liquid volume, and
temperature. The recorded data can be exported in .CSV format into a
spreadsheet file to derive the PVT parameters.
Temperature Range: up to 200°C (392°F) |
Temperature Regulation: 0.2°C |
Temperature Control System Measurement Accuracy: ±0.5°C |
Pressure Range: Atm. to 15,000 PSI / 104 MPa |
Volume Resolution: 0.01 mL |
Cell Volume: up to 500 mL |
Viewing Cell: sapphire |
Wetted Material: all heated valves, tubing, pressure transducers, and fittings are Hastelloy or Inconel |
Dimensions: All of the M9000 series products are customizable per customer's request. |
- Mercury-free design
- Computer-controlled data logging
- Visual observation cell
- Constant temperature control system
- Detection in both oil and gas condensate studies
- Designed for maximum accuracy and operator safety
- Innovative data analysis algorithms
- Comparison of current test data with historical test data
- System hardware and software customized to your specifications